Many building owners overlook fire protection systems until they are urgently needed. Minor issues like a sprinkler head out of reach, an improperly assembled fire-rated wall penetration, or an untested smoke damper before occupancy can transform a localized incident into a serious life-safety risk.

Over the years, buildings have grown more complex, codes have evolved, and insurers have often required more rigorous documentation. Fire protection has shifted from an afterthought at the end of design to a discipline that deserves attention from the earliest planning conversations through occupancy and beyond.

What makes up a fire protection system?

A sprinkler system is ineffective if the sprinklers above it wasn’t designed for the space it protects. Likewise, a fire alarm serves little purpose if no one in the building hears the alarm and evacuates intime.

Fire protection operates as a cohesive system because its components rely on each other: active suppression gear such as sprinklers, standpipes, and fire pumps contain the fire, while detection and notification devices alert occupants to evacuate. In areas where water could cause as much damage as the fire, clean-agent systems provide suppression without that trade-off.

Passive protection underpins the entire safety setup, integrating elements such as fire-rated walls, doors, dampers, and penetration assemblies, which all work to slow fire spread and give active systems and people more time to react. If any part of this system fails—such as a damper that doesn’t fit properly or a silent notification system—the whole safety network is at risk.

Factors driving the renewed focus on fire protection

Buildings now house more interior equipment than in the past, which has altered fire protection requirements. Data centers, battery backup systems, and mission critical facilities contain sensitive, often flammable devices in spaces not originally designed for them.

Lithium-ion batteries are particularly hazardous, as traditional water-based suppression methods are ineffective against them. Similarly, newer refrigerants, which replace older non-flammable ones, demand enhanced fire protection measures in mechanical areas.

Growing complexity primarily affects renovation projects, where existing buildings, originally designed for a single setup, must now accommodate new technologies and denser systems. What appears to be a simple remodel can trigger a broader compliance review than owners anticipate, involving fire alarm systems, piping, and rated assemblies throughout the structure.

Additionally, insurance providers often exert pressure beyond code standards, as underwriters on major projects tend to tailor system requirements to the building’s unique risk profile rather than just minimum code requirements.

None of this happens in a vacuum. A high-profile fire event elsewhere, whether involving electric vehicle batteries in a parking structure or another emerging hazard, can ripple outward into code changes for every similar building built afterward.

Maintaining system integrity through fire protection commissioning

Commissioning a fire protection system starts with a simple question that drives everything else: what is this system protecting, and how is it supposed to behave under emergency conditions? Once the design intent is clear, the installed system is compared against the original drawings and specifications, where discrepancies surface before they become permanent parts of the finished building.

From there, the real testing begins, reaching into nearly every corner of the system. Hydrostatic testing confirms piping holds pressure without leaking, flow testing verifies that alarm signals reach the fire panel correctly, and fire pump tests confirm the system delivers the pressure it was designed for. Fire alarm testing pushes further still, checking that detectors and pull stations trigger the right response and that voice evacuation systems are clear enough for occupants to understand where to go.

On federal and state government projects, this involvement often extends well past the design stamp, with engineers expected to stay engaged through construction rather than handing the project off to a contractor. That sustained presence is ultimately what allows a commissioning team to withhold sign-off until every system performs exactly as intended, protecting both the occupants and the building’s certificate of occupancy.

Common fire protection issues in design and construction

A four-inch fire sprinkler main and a wide mechanical air handler cannot occupy the same six inches of ceiling space. However, that exact conflict is increasingly showing up on job sites.

Sprinkler piping is often the last system routed through a ceiling. When mechanical ductwork or electrical raceways are placed without accounting for it, clashes surface mid-construction as RFIs, redesigns, and delays. Coordinated cloud-based models can help catch these conflicts earlier, provided that every trade claims its space during the design phase rather than waiting for the field to sort it out.

Cost pressures can lead to shortcuts that cause problems later. For example, skipping a nitrogen generator on a dry pipe system might reduce initial costs, but it leaves standard air—including oxygen—in the piping for years. This can cause internal steel corrosion over time. Similarly, when installers seal rated wall penetrations with fire caulking instead of using the UL-listed assembly designed for that wall’s rating, it compromises the fire-resistance. Instead of a two-hour rated wall, it may only perform like a one-hour wall.

Water supply data can cause costly surprises, particularly if uncovered too late. If hydrant testing is delayed, the project might only realize during construction that the pressure and flow are insufficient for the system’s design. This can lead to the unexpected need for a fire pump upgrade, or even a storage tank, significantly increasing the project costs.

Buried piping carries another version of the same risk. This happens when a pressure test is skipped or rushed before backfill, which can mean digging up finished landscaping to chase down a leak that should have been caught months earlier.

Fire protection remediation for existing buildings

The oxygen-driven corrosion within a dry pipe system usually reveals itself well before any failure. Rust on exposed piping in a parking garage often signals internal corrosion, and if a fire pump’s dry system air compressor runs more frequently than usual, it may indicate a small leak causing the system to repressurize more often than necessary.

Fire alarm panels often reveal the same pattern, especially if someone is paying attention. In older buildings, trouble and supervisory signals frequently build up and get silenced instead of being addressed. Over time, this practice can hide genuine issues with detectors, valves, or other components, which are then simply muted by pressing a button on the panel.

These problems frequently remain unresolved until the building is renovated. At that point, crossing certain scope thresholds may necessitate updating the entire building’s fire protection systems to meet current codes.

How Salas O’Brien can help

When you’re weighing a renovation, a new build, or a fire protection assessment for an aging building, you want a team that treats fire protection as integral to the building’s design rather than a system tacked on at the end. Salas O’Brien’s fire protection engineers bring decades of combined experience in suppression, detection, and life safety, backed by a nationwide and international network you can draw on when a project requires specialized expertise.

That experience is reinforced by a quality-control process built into every stage of design, along with shared cloud models that keep fire protection coordinated with every other discipline from day one. The result is a design that avoids the expensive surprises that arise when fire protection is treated as an afterthought.

Whether you’re navigating code requirements triggered by a renovation, working through commissioning on a mission critical facility, or trying to understand why an aging system keeps sending signals nobody’s addressed, we’re ready to help you get ahead of the problem.

Reach out to discuss your project with one of our experts. Contact us at [email protected]

For media inquiries on this article, reach out to [email protected].

Contributors
Ron Deese

Ron Deese

Ron Deese is an accomplished Design Engineer and Project Manager with three decades of experience. He has extensive engineering experience with aviation, commercial, higher education, and healthcare, as well as mission critical, along with a variety of other industries. Ron currently serves as a Senior Plumbing and Fire Protection Designer at Salas O’Brien. Contact him at: [email protected]

All Posts

Nick Santos, PE, QFPE

Nick Santos, PE, QFPE

Nick Santos designs and reviews fire protection systems for commercial, federal, aerospace, space launch, defense, and other high-hazard facilities. With 10 years of engineering experience, he specializes in fire alarm, automatic suppression, deluge and special hazard systems, smoke control, and hazardous operations, and he oversees code compliance for complex, mission-critical facilities supporting NASA, Space Force, and commercial space programs. Nick currently serves as Fire Protection Department Lead at Salas O’Brien. Contact him at [email protected]

All Posts

Tim Campbell, PE, LEED AP

Tim Campbell, PE, LEED AP

Tim Campbell designs and commissions fire protection and plumbing systems for a variety of facilities, including commercial offices, hotels, mixed-use, retail, and sensitive data storage areas. As a Qualified Fire Protection Engineer, he oversees compliance and code requirements, facilitates water supply evaluations and hydraulic calculations, inspects and tests sprinkler systems, fire pumps, and fire alarms, and provides project oversight for all areas involving Life Safety. Tim currently serves as Senior Vice President at Salas O’Brien. Contact him at [email protected]

All Posts